public class ConfigEmission extends Object
Element of Configuration
Constructor and Description |
---|
ConfigEmission() |
Modifier and Type | Method and Description |
---|---|
EmsDes |
getEmsClass()
Get a three to five characters code, derived from the table below,
representing the emission classification.
|
FreqM |
getNecessaryBwMax()
Get the maximum necessary bandwidth in the case of a range of values.
|
FreqM |
getNecessaryBwMin()
Get the necessary bandwidth which is defined as the value in MHz, for a
given class of emission, the width of the frequency band which is just
sufficient to ensure the transmission of information at the rate and with
the quality required under specified conditions.
|
boolean |
isSet()
Determine if the required fields in this SSRF data type instance are set.
|
boolean |
isSetEmsClass()
Determine if the EmsClass is configured.
|
boolean |
isSetNecessaryBwMax()
Determine if the NecessaryBwMax is configured.
|
boolean |
isSetNecessaryBwMin()
Determine if the NecessaryBwMin is configured.
|
void |
setEmsClass(EmsDes value)
Set a three to five characters code, derived from the table below,
representing the emission classification.
|
void |
setNecessaryBwMax(FreqM value)
Set the maximum necessary bandwidth in the case of a range of values.
|
void |
setNecessaryBwMin(FreqM value)
Set the necessary bandwidth which is defined as the value in MHz, for a
given class of emission, the width of the frequency band which is just
sufficient to ensure the transmission of information at the rate and with
the quality required under specified conditions.
|
String |
toString()
Get a string representation of this ConfigEmission instance configuration.
|
ConfigEmission |
withEmsClass(String value)
Set a three to five characters code, derived from the table below,
representing the emission classification.
|
ConfigEmission |
withNecessaryBwMax(Double value)
Set the maximum necessary bandwidth in the case of a range of values.
|
ConfigEmission |
withNecessaryBwMin(Double value)
Set the necessary bandwidth which is defined as the value in MHz, for a
given class of emission, the width of the frequency band which is just
sufficient to ensure the transmission of information at the rate and with
the quality required under specified conditions.
|
public EmsDes getEmsClass()
EmsDes
instancepublic void setEmsClass(EmsDes value)
value
- a EmsDes
instancepublic boolean isSetEmsClass()
public FreqM getNecessaryBwMax()
[XSL ERR MINMAX] If US:NecessaryBwMax is used, it MUST be greater than US:NecessaryBwMin..
FreqM
instancepublic void setNecessaryBwMax(FreqM value)
[XSL ERR MINMAX] If US:NecessaryBwMax is used, it MUST be greater than US:NecessaryBwMin..
value
- a FreqM
instancepublic boolean isSetNecessaryBwMax()
public FreqM getNecessaryBwMin()
FreqM
instancepublic void setNecessaryBwMin(FreqM value)
value
- a FreqM
instancepublic boolean isSetNecessaryBwMin()
public ConfigEmission withEmsClass(String value)
value
- An instances of type String
.public ConfigEmission withNecessaryBwMax(Double value)
[XSL ERR MINMAX] If US:NecessaryBwMax is used, it MUST be greater than US:NecessaryBwMin.
value
- An instances of type Double
.public ConfigEmission withNecessaryBwMin(Double value)
value
- An instances of type Double
.public String toString()
public boolean isSet()
ConfigEmission
has no configuration requirements.
Copyright © 2016 OpenSSRF.org. All rights reserved.