Package | Description |
---|---|
us.gov.dod.standard.ssrf._3_1.transmitter |
Modifier and Type | Method and Description |
---|---|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPAdaptiveDriverDesc(String value)
Set the condition which controls, or can be associated with, the signal MOP
variations.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPAdaptiveDriverRuleDesc(String value)
Set the rule which describes the signal MOP variations.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPAMPercentModulation(Double value)
Set the AM Percent Modulation is the ratio (expressed as a percentage)
between the amplitude variation and the maximum amplitude
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPChangeRateAM(Double value)
Set In Data Item US:MOPChangeRateAM (US), enter the change in amplitude
within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPChangeRateCW(Double value)
Set In Data Item US:MOPChangeRateCW (US), enter the change in continuous
wave frequency within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPChangeRateFM(Double value)
Set In Data Item US:MOPChangeRateFM (US), enter the change in frequency
within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPChangeRatePM(Double value)
Set In Data Item US:MOPChangeRatePM (US), enter the change in phase angle
within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPContinuous(ListCBO value)
Set In Data Item US:MOPContinuous (US), indicate whether MOP or CW
modulation is Discrete or Continuous.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPID(String value)
Set In Data Item US:MOPID (US), enter a unique identifier (within the
TxMode) for the MOP data.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPMeanValueAM(Double value)
Set In Data Item US:MOPMeanValueAM (US), enter the average amplitude for a
signal which changes on a non-patterned basis within a pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPMeanValueCW(Double value)
Set In Data Item US:MOPMeanValueCW (US), enter the average continuous wave
frequency for a signal which changes on a non-patterned basis within a
pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPMeanValueFM(Double value)
Set In Data Item US:MOPMeanValue (US), enter the average frequency for a
signal which changes on a non-patterned basis within a pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPMeanValuePM(Double value)
Set In Data Item US:MOPMeanValue (US), enter the average phase angle for a
signal which changes on a non-patterned basis within a pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPNumElements(Integer value)
Set In Data Item US:MOPNumElements (US), enter the number of discrete
FREQ/PHASE/AMP values transmitted in a patterned sequence (i.e., any
repeated values are counted each time)
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPOffTime(Double value)
Set In Data Item US:MOPOffTime (US), enter the duration of the state of the
modulated waveform with the absence of energy.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPOnTime(Double value)
Set In Data Item US:MOPOnTime (US), enter the duration of the one on-time
related to the binary form of amplitude modulation called on-off keying.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPPatternName(String value)
Set In Data Item MOPPatternName (US), enter a freeform text name for the
pattern (e.g., Phase Alpha).
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPPatternPeriod(Double value)
Set In Data Item US:MOPPatternPeriod (US), enter the duration of one
complete cycle of Frequency, Phase or Amplitude variations for a signal
which changes on a patterned basis, within a pulse, for pulsed signals.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPPatternType(ListUS7 value)
Set In Data Item US:MOPPatternType (US), indicate whether MOP or CW
characteristics are Patterned, Non-Patterned, Adaptive, or Unmodulated.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPPulseDurationLink(Double value)
Set In Data Item US:MOPPulseDurationLink (US), enter the Discrete PD value
which is associated with the selected MOP name (i.e., the name in the MOP
Pattern List).
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPTimeBWProduct(Double value)
Set In Data Item US:MOPTimeBWProduct (US), enter the time-bandwidth product
of the waveform (actual PD times instantaneous bandwidth).
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPType(ListUSX value)
Set In Data Item MOPType (US), indicate if the information imprinted on the
pulse is modulated by amplitude (AM), frequency (FM), phase (PM), or is a
continuous wave (CW).
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMaxAM(Double value)
Set In Data Item US:MOPValueMaxAM (US), enter the maximum change in
amplitude within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMaxCW(Double value)
Set In Data Item US:MOPValueMaxCW (US), enter the maximum change in
continuous wave frequency within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMaxFM(Double value)
Set In Data Item US:MOPValueMaxFM (US), enter the maximum change in
frequency within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMaxPM(Double value)
Set In Data Item US:MOPValueMaxPM (US), enter the maximum change in phase
angle within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMinAM(Double value)
Set In Data Item US:MOPValueMinAM (US), enter the minimum change in
amplitude within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMinCW(Double value)
Set In Data Item US:MOPValueMinCW (US), enter the minimum change in
continuous wave frequency within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMinFM(Double value)
Set In Data Item US:MOPValueMinFM (US), enter the minimum change in
frequency within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withMOPValueMinPM(Double value)
Set In Data Item US:MOPValueMinPM (US), enter the minimum change in phase
angle within the pulse.
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withObservedMOPSweep(Collection<ObservedMOPSweep> values)
Set the US:ObservedMOPSweep
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withObservedMOPSweep(ObservedMOPSweep... values)
Set the US:ObservedMOPSweep
|
ObservedMOPAnalysis |
ObservedMOPAnalysis.withSignalType(ListCMO value)
Set In Data Item SignalType (US), indicate the specific type of modulation
used/detected.
|
Modifier and Type | Method and Description |
---|---|
Set<ObservedMOPAnalysis> |
TxMode.getObservedMOPAnalysis()
Get the US:ObservedMOPAnalysis
|
Modifier and Type | Method and Description |
---|---|
TxMode |
TxMode.withObservedMOPAnalysis(ObservedMOPAnalysis... values)
Set the US:ObservedMOPAnalysis
|
Modifier and Type | Method and Description |
---|---|
TxMode |
TxMode.withObservedMOPAnalysis(Collection<ObservedMOPAnalysis> values)
Set the US:ObservedMOPAnalysis
|
Copyright © 2016 OpenSSRF.org. All rights reserved.