ObservedPulseAnalysis |
ObservedPulseAnalysis.withFallTime(Double value)
Set the time required for a pulse to fall from 90% to 10 percent of the
mean peak amplitude of its voltage waveform/envelope.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withNumPDPositions(Integer value)
Set the number of pulses (i.e., positions) in a repeating sequence of
pulses which has multiple (2 or more) PD values.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withNumPDValues(Integer value)
Set the number of discrete PD values (i.e., elements) in a repeating
sequence of pulses which has multiple (2 or more) PD values.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withNumPRIElements(Integer value)
Set the number of discrete PRI values in a repeating sequence of discrete
PRIs.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withNumPRIPositions(Integer value)
Set the number of time intervals between pulses or pulse groups, or the
number of PRI dwell groups, in a repeating PRI sequence which uses discrete
PRI values.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withObservedPulseValues(Collection<ObservedPulseValues> values)
Set the US:ObservedPulseValues
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withObservedPulseValues(ObservedPulseValues... values)
Set the US:ObservedPulseValues
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDAdaptiveRuleDesc(String value)
Set the rule which describes the signal PD variations (aka.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDContinuous(ListCBO value)
Set In Data Item PDContinuous (US), indicate whether pulse-to-pulse PD
variations are Discrete or Continuous.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDDwellMax(Double value)
Set the maximum time duration for a complete dwell/group of pulses which
all have the same PD value.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDDwellMin(Double value)
Set the minimum time duration for a complete dwell/group of pulses which
all have the same PD value.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDExtremeMax(Double value)
Set the maximum PD value that represents 100% of observed values.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDExtremeMin(Double value)
Set the minimum PD value that represents 100% of observed values.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDMax(Double value)
Set the highest discrete PD value in a repeating sequence of pulses which
has multiple PD values
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDMean(Double value)
Set the average PD of a signal which changes PD values on a non-patterned
basis.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDMedian(Double value)
Set the PD value that the signal most often used, based on a statistical
study.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDMin(Double value)
Set the delta lowest discrete PD value in a repeating sequence of pulses
which has multiple PD values
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDPatternPeriod(Double value)
Set the time duration for one complete cycle of a repeating sequence of
pulses which has multiple (2 or more) PD values; the time duration shall go
from a point in one cycle to a like point in the next cycle.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDPatternType(ListUS7 value)
Set In Data Item PDPatternType (US), Indicate whether PD is unmodulated or
pulse-to-pulse PD variations are Patterned, Non-Patterned, or Adaptive.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDSequenceDesc(String value)
Set a freetext description of the PD Sequence.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDStdDev(Double value)
Set the standard deviation of the data sample used to calculate PD Mean.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDStep(Double value)
Set the Step between adjacent PD values; pertains to discrete PD
variations.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDTypicalMax(Double value)
Set the upper end of the range of PD values that represents 95% of observed
values, from a statistical study.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPDTypicalMin(Double value)
Set the lower end of the range of PD values that represents 95% of observed
values, from a statistical study
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFChangeRate(Double value)
Set the rate of change for PD variations expressed as PD change per unit of
time.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFExtremeMax(Double value)
Set the minimum Observed PRF in the signal sample.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFExtremeMin(Double value)
Set the minimum Observed PRF in the signal sample.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFMax(Double value)
Set the highest discrete PRI value (convert PRI to PRF) which are found in
a single intercept that contains the complete PRI characteristics for that
specific data set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFMin(Double value)
Set the lowest discrete PRI value (convert PRI to PRF) which are found in a
single intercept that contains the complete PRI characteristics for that
specific data set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFTypicalMax(Double value)
Set the upper end of the range of PRF values that represents 95% of
observed values, from a statistical study.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRFTypicalMin(Double value)
Set the lower end of the range of PRF values that represents 95% of
observed values, from a statistical study
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIAdaptiveDriverDesc(String value)
Set the condition which controls or can be associated with the signal PRI
variations (aka, interpulse modulation changes).
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIAdaptiveRuleDesc(String value)
Set the rule which describes the signal PRI variations (aka, interpulse
modulation changes)
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIAnomalousValues(String value)
Set any regularly occurring signal values which do not fit in any of the
other PRI related fields.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIBasicClockPeriod(Double value)
Set the fundamental period of the emitter clock which is used to generate
the subject signal PRIs
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIChangeRate(Double value)
Set the PRI change per unit of time, measured over a significant portion of
the waveform.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIContinuous(ListCBO value)
Set In Data Item PRIContinuous (US), Indicate whether pulse-to-pulse PRI
variations are Discrete or Continuous.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRICountdown(Integer value)
Set the integer (aka, count or countdown) associated with the PRI Crystal
value to provide the Pattern Period.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRICountdownKey(Integer value)
Set the integer (aka, count or countdown) used to generate the PRI from the
PRI Crystal value.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIExtremeMax(Double value)
Set the maximum observed PRI value, from a statistical study of a 100% data
set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIExtremeMin(Double value)
Set the minimum observed PRI value, from a statistical study of a 100% data
set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIFramePeriod(Double value)
Set the time difference between a point on the leading edge of the frame
marker (or an alternate pulse in the frame), to the similar point on the
leading edge of the frame marker (or the alternate pulse) in the
next/consecutive frame.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIFrameRate(Double value)
Set the rate of frame generation during the Pulse Repetition Interval.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIGroupPulseSpacing(Double value)
Set the time difference between a point on the leading edge of the subframe
marker (or an alternate pulse in the subframe), to the similar point on the
leading edge of the subframe marker (or the alternate pulse in the
subframe) in the next/consecutive frame.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIGroupSpacing(Double value)
Set the PRI between two groups of pulses which both have constant but
different PRIs (aka, the PRI between consecutive PRI dwell groups).
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIMean(Double value)
Set the average PRI value for a signal which changes PRI values on a
non-patterned basis.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIMedian(Double value)
Set the observed PRI value that the signal most often used based on
statistical study of a data set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIMedianCountdowns(String value)
Set the observed PRI Crystal Counts used to generate the PRIs used most
often by the signal, based on statistical study of a data set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIPatternPeriod(Double value)
Set the time duration for one complete cycle of a repeating PRI sequence.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIPatternType(ListUS7 value)
Set whether the PRI is unmodulated or pulse-to-pulse PRI variations are
Patterned, Non-Patterned, or Adaptive.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIPulsesPerGroup(Integer value)
Set the number of pulses in a pulse group.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRISequenceDesc(String value)
Set a free text description of the PRI Sequence.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIStability(Double value)
Set the variation of a mean PRI value measured from one time to another
time
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIStabilitySamplePeriod(Double value)
Set the time interval used to determine the PRI stability value.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIStdDev(Double value)
Set the standard deviation associated with the data set used to calculate
the values entered in the PRI Mean fields
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRIStep(Double value)
Set the delta between the Most Probable observed PRI values of adjacent and
discrete PRI.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRISubframePeriod(Double value)
Set the time difference between a point on the leading edge of the subframe
marker (or an alternate pulse in the subframe), to the similar point on the
leading edge of the subframe marker (or the alternate pulse in the
subframe) in the next/consecutive frame.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRISubframeRate(Double value)
Set the number of subframes detected during each PRI Subframe period.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRITimingShift(Double value)
Set the PRI timing shift value, on Emitters with repeated timing shifts of
a predictable magnitude, but not predictable timing.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRITypicalMax(Double value)
Set the upper end of the range of PRI values that represent 95% of the
signal observed PRI values, from a statistical study of a data set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withPRITypicalMin(Double value)
Set the lower end of the range of PRI values that represent 95% of the
signal observed PRI values, from a statistical study of a data set.
|
ObservedPulseAnalysis |
ObservedPulseAnalysis.withRiseTime(Double value)
Set the time required for a pulse to rise from 10% to 90 percent of the
mean peak amplitude of the voltage pattern.
|
Modifier and Type | Method and Description |
---|---|
Set<ObservedPulseAnalysis> |
TxMode.getObservedPulseAnalysis()
Get the US:ObservedPulseAnalysis
|
Modifier and Type | Method and Description |
---|---|
TxMode |
TxMode.withObservedPulseAnalysis(ObservedPulseAnalysis... values)
Set the US:ObservedPulseAnalysis
|
Modifier and Type | Method and Description |
---|---|
TxMode |
TxMode.withObservedPulseAnalysis(Collection<ObservedPulseAnalysis> values)